Most renovations we see in South Florida are not empty buildings. They are hotels selling rooms, hospitals treating patients and assisted living facilities where residents live every day. The building has to keep working while we rip out and replace the systems that keep it working.

That is a different kind of job from new construction. Here is how we approach it across Broward, Palm Beach and Miami Dade, and why we push for design build on it.

Why design build fits occupied renovation

In an occupied building, the plan changes the minute you open a ceiling. Old drawings are wrong. Conduit runs where nobody expected. Duct is undersized. On a traditional bid job, every surprise turns into an RFI, a redesign and a change order while the building waits.

With design build, the people designing the electrical and HVAC are on the same team as the people installing it. We hold both the electrical license (EC13006438) and the A/C license (CAC1825204). When we find something behind a wall, the fix gets designed and built in one conversation. And the owner has one contract and one party responsible for the result. Our construction page shows the kind of work we take on.

Phasing is the whole job

The heart of an occupied renovation is the phasing plan. It answers questions like:

  • Which floors or wings come offline, and in what order?

  • How do the rooms that stay open keep power, cooling and fire alarm coverage?

  • Where do temporary feeds, temporary air or rental equipment sit?

  • When are the shutdowns, and who has to approve each one?

A good phasing plan is written before demo starts and updated every week. It is the document the GM, the facility director or the administrator actually reads.

Hotels: rooms are inventory

In a hotel, every room you take offline is revenue the property does not get. So we work in blocks of floors or stacks, turn them fast and give them back. Noisy work gets scheduled around guest hours. Corridors and elevators stay clean and usable. Cooling stays on for occupied floors, because humidity in a South Florida hotel turns into mold quickly.

Properties along Fort Lauderdale beach, Miami Beach and Boca Raton all deal with the same pressure: keep the guests happy while the building gets rebuilt around them.

Hospitals: approvals and infection control come first

In Florida, renovating building systems at a hospital or surgery center needs approval from the AHCA Office of Plans and Construction before construction starts, with sealed documents from Florida registered design professionals. AHCA then surveys the work before the new spaces or systems go into use. That review time belongs in the schedule.

Inside the building, the Joint Commission expects a pre construction risk assessment covering air quality, infection control, utilities, noise and vibration, plus an infection control risk assessment that sets barriers, negative air, cleaning and traffic rules. When fire alarm or other life safety features are impaired, interim life safety measures apply, and a long fire alarm outage in an occupied building means a fire watch.

Our crews have to know and follow all of it. A dust barrier that leaks is not a small problem in a hospital.

ALFs: residents live here

An assisted living facility is a home. Residents have routines, some have memory care needs, and change is stressful for them. Work hours, noise and who is in the hallway matter more than in almost any other building.

There is also a code reason to plan carefully. Under Florida's ALF emergency power rule, a renovation that changes the systems behind emergency power and cooling means the facility has to amend its emergency power plan and resubmit it to the county emergency management agency. If your renovation touches the generator, the transfer switch or the HVAC serving the cooled area, plan that resubmission up front. Our post on Florida ALF generator requirements covers the rule in more detail.

Fire alarm moves with everything else

Every renovation touches the fire alarm system. Devices come down with ceilings, zones change with new walls, and new HVAC equipment needs duct detectors and shutdown tie ins. We do fire alarm construction under our electrical license, so it stays in the same phasing plan as the power and the HVAC instead of being a separate trade showing up late.

What owners should do first

Get the existing conditions surveyed before the design is final. Find out what drawings exist and how wrong they are. Decide how much of the building can be offline at once. Then bring the contractor in early enough to shape the phasing, not just price it.

Frequently asked questions

Can a building stay open during a full electrical and HVAC renovation?

Yes, with a phasing plan. Work moves floor by floor or wing by wing, and the occupied areas keep power, cooling and fire alarm coverage the whole time.

Why use design build for a renovation?

Because surprises behind walls get solved by one team in one conversation, instead of turning into RFIs and change orders. The owner also has one contract and one party responsible.

Do hospital renovations need state approval?

In Florida, yes. The AHCA Office of Plans and Construction approves the plans before work starts and surveys the work before it goes into use.

Does an ALF renovation affect the emergency power plan?

It can. If the work changes the generator, transfer switch or the HVAC serving the cooled area, the plan has to be amended and resubmitted to the county.

Talk to us about your renovation

Pacman HVAC Electric Fire has worked from 751 Shotgun Rd in Sunrise since 1999 on commercial buildings across Broward, Palm Beach and Miami Dade. Call 954.577.7923, Monday to Friday 7 AM to 5 PM, or request a quote to talk through a design build renovation. See more of our construction work.